SolarMax P series

  SolarMax 2000P SolarMax 3000P SolarMax 4000P SolarMax 4600P SolarMax 5000P
Input values
MPP voltage range 1) 210 .. 480 V 310 .. 480 V 210 .. 480 V 240 .. 480 V 260 .. 480 V

Total MPP operating voltage range

120 ... 580 V 120 ... 580 V 120 ... 580 V 120 ... 580 V 120 ... 580 V
Minimum DC voltage 120 V 120 V 120 V 120 V 120 V
Maximum DC voltage 600 V 600 V 600 V 600 V 600 V
Maximum DC current 10 A 10 A 10 + 10 A 10 + 10 A 10 + 10 A
Number of MPP trackers 1 1 2 2 2
Number of string connections 1 1 2 2 2
Connection type Wieland PST40i1 (MC4 identical in design)
Output values
Rated output power2) 2’000 W 3’000 W 4’000 W 4’600 W 5’000 W
Maximum apparent output power2) 2’000 VA 3’000 VA 4’000 VA 4’600 VA 5’000 VA
Maximum AC current 9 A 13.5 A 17.5 A 22 A 22 A
Nominal mains voltage / range 230 V / 184 .. 276 V
Mains nominal frequency / range 50 Hz / 45 Hz…55 Hz
Power factor cos(φ) Adjustable from 0.8 overexcited to 0.8 underexcited
Distortion factor at rated output power < 3 %
Connection type Terminal (2.5 – 10 mm2)
Grid connection Single phase (L / N / PE)
Power input at night 0W
Efficiency
Maximum efficiency 97.5 % 97.5 % 98.0 % 98.0 % 98.0 %
Europ. Efficiency 97.0 % 97.0 % 97.5 % 97.5 % 97.5 %
Ambient conditions
Protection type IP65
Ambient temperature range (for rated power output) -20 °C…+60 °C (+45°C)
Relative humidity 0…100% (condensation)
Max. operating level above sea level 2000m (without derating)
Fire protection class V0 
Noise emissions < 30 dB(A) (↔ 1.5 m)
Configuration
Display Graphic LC display with backlighting and status LED
Inverter topology HERIC®, transformerless
DC disconnector Integrated
Data logger Energy yield, peak output and operating hours of the last 31 days, 12 months, 10 years.
Performance curves of the last 7 days.
Fault current monitoring Internal, AC/DC sensitive
Housing / service cover Aluminium / plastic ASA+PC
Surge protection DC and AC Requirement class D (VDE 0675-6) and/or type 3 (EN 61643-11)
Standards & guidelines
CE-compliant Yes
EMC EN 61000-3-2 / EN 61000-3-3 / EN 61000-3-11 / EN 61000-3-12 / EN 61000-6-2 /
EN 61000-6-3
Grid connection

VDE 0126-1-1 A1:2012 / VDE-AR-N 41053)/ CEI 0-214) / RD 661 / RD 1699 / G83/2 /
G59/2 / PPC Guide / C10/11 / EN 50438 / AS4777

Device safety IEC/ EN 62109-1/ -2
Interfaces
Data communication RS485 / Ethernet (Plug&Play)
Status signalling contact With optional I/O module
Connection ripple control signal receiver
Connection of external lightning protection control
Connection external grid monitoring
Connection of external energy meter
Weight & dimensions
Weight 17 kg 17 kg 19 kg 19 kg 19 kg
Dimensions in mm (W x H x D) 476 x 360 x 180mm
Warranty
Standard warranty 5 years
Warranty extensions to 10, 15, 20, or 25 years 

1) For AC rated power output
2) Depending on the country setting, deviating values are possible. Details can be found at Downloads
3) not for 5000P
4) for plants ≤ 6 kW

All rights, amendments and errors reserved.

SolarMax 5000P efficiency curve